PCE-779N Infrared thermometer

Compact infrared thermometer to measure surface temperatures Incl. thermocouple measurement  Adjustable emissivity  Difference measuring function  Tripod thread  MIN, MAX and alarm function  LED light The infrared thermometer PCE-779N can be used for quick temperature measurements. This can be done in two different ways: either without contact or by means of a thermocouple. The infrared thermometer is suitable for nearly all surfaces. Since the infrared thermometer allows non-contacting measurement, even high temperatures can be measured from a safe distance. By means of the integrated dual laser of the infrared thermometer PCE-779N, the user can target the measuring spot very precisely. The infrared thermometer has a variety of functions, including the MAX and MIN functions as well as the average and the difference function, which makes the infrared thermometer useful for many applications, including contacting, but also non-contacting measurements. The infrared thermometer is typically used for e. g. food monitoring, different hygiene-related controls, road construction, switch cabinet and production monitoring as well as for measuring motor temperatures. - Dual laser for targeting Additional thermocouple measurement - Easy handling - Large display - Difference value measurement Average measurement - MIN / MAX value measurement - Alarm function

PCE-779N Infrared thermometer
Measurement range Infrared measurement: -60 … 760°C / -76 … 1400°F
Thermocouple measurement: -64 … 1400°C / -83.2 … 2552°F
Accuracy (Tobj=15 ... 35°C, Tenv= 25°C) Infrared measurement: ± 1°C / 1.8°F
Thermocouple measurement: ±1% of reading
or ±1°C / 1.8°F (higher value applies)
Accuracy (Tenv= 23 ±3 °C)

Infrared measurement: Tobj = – 60 … 0 ±(2+0.05/°C/°F) °C, Tobj= 0 … 760: ±2% of reading or ± 2°C / 3.6°F (higher value applies)
Thermocouple measurement: ±1% of reading
or ±1°C / 1.8°F (higher value applies)
(measurement below Tenv= 23 ± 6°C / 42.8°F)

Optical resolution 30 : 1
Response time 1 s
Emissivity 0.95 (default)
0.1 … 1.0 (adjustable)
Resolution 0.1°C / 0.18°F at -83.2 … 999.9°C / -117.7 … 1831.8°F… , otherwise 1°C / 1.8°F
Functions MAX, MIN, difference, average
Display LCD with backlight
Power supply 2 x AAA (Alkaline)
Battery life Without laser: at least 30 h
With laser and LED: at least 3 h
Operating conditions 0 … 50°C / 32 … 122°F
Laser Class 2
Weight 256 g / < 1 lb (incl. batteries)
Dimensions 119.2 x 47.5 x 171.8 mm / 4.7 x 1.9 x 6.8 in

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

PCE-779N Infrared thermometer

Compact infrared thermometer to measure surface temperatures Incl. thermocouple measurement  Adjustable emissivity  Difference measuring function  Tripod thread  MIN, MAX and alarm function  LED light The infrared thermometer PCE-779N can be used for quick temperature measurements. This can be done in two different ways: either without contact or by means of a thermocouple. The infrared thermometer is suitable for nearly all surfaces. Since the infrared thermometer allows non-contacting measurement, even high temperatures can be measured from a safe distance. By means of the integrated dual laser of the infrared thermometer PCE-779N, the user can target the measuring spot very precisely. The infrared thermometer has a variety of functions, including the MAX and MIN functions as well as the average and the difference function, which makes the infrared thermometer useful for many applications, including contacting, but also non-contacting measurements. The infrared thermometer is typically used for e. g. food monitoring, different hygiene-related controls, road construction, switch cabinet and production monitoring as well as for measuring motor temperatures. - Dual laser for targeting Additional thermocouple measurement - Easy handling - Large display - Difference value measurement Average measurement - MIN / MAX value measurement - Alarm function

PCE-779N Infrared thermometer
Measurement range Infrared measurement: -60 … 760°C / -76 … 1400°F
Thermocouple measurement: -64 … 1400°C / -83.2 … 2552°F
Accuracy (Tobj=15 ... 35°C, Tenv= 25°C) Infrared measurement: ± 1°C / 1.8°F
Thermocouple measurement: ±1% of reading
or ±1°C / 1.8°F (higher value applies)
Accuracy (Tenv= 23 ±3 °C)

Infrared measurement: Tobj = – 60 … 0 ±(2+0.05/°C/°F) °C, Tobj= 0 … 760: ±2% of reading or ± 2°C / 3.6°F (higher value applies)
Thermocouple measurement: ±1% of reading
or ±1°C / 1.8°F (higher value applies)
(measurement below Tenv= 23 ± 6°C / 42.8°F)

Optical resolution 30 : 1
Response time 1 s
Emissivity 0.95 (default)
0.1 … 1.0 (adjustable)
Resolution 0.1°C / 0.18°F at -83.2 … 999.9°C / -117.7 … 1831.8°F… , otherwise 1°C / 1.8°F
Functions MAX, MIN, difference, average
Display LCD with backlight
Power supply 2 x AAA (Alkaline)
Battery life Without laser: at least 30 h
With laser and LED: at least 3 h
Operating conditions 0 … 50°C / 32 … 122°F
Laser Class 2
Weight 256 g / < 1 lb (incl. batteries)
Dimensions 119.2 x 47.5 x 171.8 mm / 4.7 x 1.9 x 6.8 in