The CX810 Coating Thickness Gauge is an advanced device for non-destructive measurement of coating thickness. It precisely measures non-magnetic coatings like paint, enamel, and chrome on ferrous metals, as well as insulating coatings on non-ferrous metals. Designed with a high-resolution external probe, it integrates magnetic induction and eddy current technologies for unmatched accuracy and performance. With a measurement range of up to 5000μm for ferrous (Fe) and 3000μm for non-ferrous (NFe) metals, this gauge is ideal for industrial, automotive, and laboratory applications.

Features

  • Wide Measurement Range: Measures up to 5000μm for Fe and 3000μm for NFe materials.
  • High Accuracy: ±(2%+1μm) for precise coating analysis.
  • Enhanced Resolution: 0.1μm for detailed measurements below 100μm.
  • Dual Technology Probe: Combines magnetic induction and eddy current effects for versatility.
  • Comprehensive Data Display: Curve, bar chart, and trend chart options for statistical analysis.
  • Backlit Display: 2.4-inch color screen with adaptive brightness for clear visibility in any lighting.
  • Flexible Units: Provides measurements in μm, mils, mm, and inches.
  • Custom Alerts: Configurable upper and lower limits with audible notifications.
  • Portable Design: Lightweight housing with ergonomic build for on-the-go use.
  • Long Battery Life: Powered by two 1.5V AA alkaline batteries.
Measurement Range 
Fe

 0–5000μm

 

NFe

 0–3000μm

 

Resolution

0.1μm (0–99.9μm)

 

 

1μm (>100μm)

 

Accuracy

 ±(2%+1μm)

 

Minimum Substrate Thickness 
Fe

 0.20mm

 

NFe

 0.03mm

 

Probe Diameter

 17mm

 

Probe Type

 External with integrated magnetic induction and eddy current technologies

 

Units Supported

 μm, mils, mm, inches

 

Display

 2.4-inch color screen with self-adaptive brightness

 

Statistics Features

 Maximum, minimum, mean, standard deviation, coefficient of variation

 

Calibration

 Zero calibration and multi-point calibration

 

Weight

 200g

 

Power Supply

 2 x 1.5V AA alkaline batteries

 

Dimensions 
Housing

 113 x 53 x 25 mm

 

Wire

 ⌀3.5 x 1000 mm

 

Probe

 ⌀17 x 67 mm

 

Standards/Certifications

 CE, ROHS, ISO 2178, ISO 2360, GB/T 4956-2003, GB/T 4957-2003

 

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

What coatings can the CX810 measure?

The CX810 measures non-magnetic coatings on ferrous metals and insulating coatings on non-ferrous metals.

What is the maximum measurement range?

It can measure up to 5000μm on ferrous metals and 3000μm on non-ferrous metals.

What kind of display does the device have?

The CX810 features a 2.4-inch color screen with adaptive backlight brightness.

Can the device store and analyze data?

Yes, it provides statistical analysis and visual data representation through charts.

What is the device's accuracy?

The accuracy is ±(2%+1μm), ensuring reliable results for every measurement.

How is the CX810 powered?

The device is powered by two 1.5V AA alkaline batteries. 

Coating Thickness Gauge CX810

The CX810 Coating Thickness Gauge is an advanced device for non-destructive measurement of coating thickness. It precisely measures non-magnetic coatings like paint, enamel, and chrome on ferrous metals, as well as insulating coatings on non-ferrous metals. Designed with a high-resolution external probe, it integrates magnetic induction and eddy current technologies for unmatched accuracy and performance. With a measurement range of up to 5000μm for ferrous (Fe) and 3000μm for non-ferrous (NFe) metals, this gauge is ideal for industrial, automotive, and laboratory applications.

Features

  • Wide Measurement Range: Measures up to 5000μm for Fe and 3000μm for NFe materials.
  • High Accuracy: ±(2%+1μm) for precise coating analysis.
  • Enhanced Resolution: 0.1μm for detailed measurements below 100μm.
  • Dual Technology Probe: Combines magnetic induction and eddy current effects for versatility.
  • Comprehensive Data Display: Curve, bar chart, and trend chart options for statistical analysis.
  • Backlit Display: 2.4-inch color screen with adaptive brightness for clear visibility in any lighting.
  • Flexible Units: Provides measurements in μm, mils, mm, and inches.
  • Custom Alerts: Configurable upper and lower limits with audible notifications.
  • Portable Design: Lightweight housing with ergonomic build for on-the-go use.
  • Long Battery Life: Powered by two 1.5V AA alkaline batteries.
Measurement Range 
Fe

 0–5000μm

 

NFe

 0–3000μm

 

Resolution

0.1μm (0–99.9μm)

 

 

1μm (>100μm)

 

Accuracy

 ±(2%+1μm)

 

Minimum Substrate Thickness 
Fe

 0.20mm

 

NFe

 0.03mm

 

Probe Diameter

 17mm

 

Probe Type

 External with integrated magnetic induction and eddy current technologies

 

Units Supported

 μm, mils, mm, inches

 

Display

 2.4-inch color screen with self-adaptive brightness

 

Statistics Features

 Maximum, minimum, mean, standard deviation, coefficient of variation

 

Calibration

 Zero calibration and multi-point calibration

 

Weight

 200g

 

Power Supply

 2 x 1.5V AA alkaline batteries

 

Dimensions 
Housing

 113 x 53 x 25 mm

 

Wire

 ⌀3.5 x 1000 mm

 

Probe

 ⌀17 x 67 mm

 

Standards/Certifications

 CE, ROHS, ISO 2178, ISO 2360, GB/T 4956-2003, GB/T 4957-2003

 

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

What coatings can the CX810 measure?

The CX810 measures non-magnetic coatings on ferrous metals and insulating coatings on non-ferrous metals.

What is the maximum measurement range?

It can measure up to 5000μm on ferrous metals and 3000μm on non-ferrous metals.

What kind of display does the device have?

The CX810 features a 2.4-inch color screen with adaptive backlight brightness.

Can the device store and analyze data?

Yes, it provides statistical analysis and visual data representation through charts.

What is the device's accuracy?

The accuracy is ±(2%+1μm), ensuring reliable results for every measurement.

How is the CX810 powered?

The device is powered by two 1.5V AA alkaline batteries. 

قارن بين المنتجات

{"one"=>"حدد 2 أو 3 عناصر للمقارنة", "other"=>"تم اختيار {{ count }} من 3 عناصر"}

حدد العنصر الأول للمقارنة

حدد العنصر الثاني للمقارنة

حدد العنصر الثالث للمقارنة

يقارن