The main features are :-

The Kanomax PIEZOBALANCE Dust Monitor 3522  is a unique respirable aerosol monitor, providing direct mass concentration of particulates using PIEZOBALANCE technology; ideal especially for oil mist monitoring.

  • Measures PM 10, Respirable, or PM 2.5 particle matters
  • Real-time measurements of dust concentration
  • Data logging up to 500 measurements
  • Simple cleaning mechanism for easy maintenance
  • Complete with data processing software, RS 232C cable, cleaning kit, Ni-MH battery pack, AC adapter, carrying case and calibration certification.
  • The Kanomax 3521 is equipped with 4 and 10µm impactors while the 3522 is equipped with a 2.5µm impactor.
  •  Unlike conventional dust meters, which count particles, a PIEZOBALANCE dust meter like the 3521 or 3522 “weighs” mass concentration of particulates.
  •  As an air sample enters the system, it travels through the impactor, which captures and removes larger particulates away from the sample.
  • Smaller particulates become electrically charged and deposited on the piezo-crystal.
  • The total mass of the deposited particulates affects the piezo-crystal’s frequency.
  • Since the change in frequency is proportional to the mass of the particulates, the actual weight of the particulates is obtained

The main working principle of Piezobalance dust monitor is when an air sample enters the system, it travels through the impactor, which captures and removes larger particulates away from the sample. Smaller particulates become electrically charged and deposited on the piezo-crystal. The total mass of the deposited particulates affects the piezo-crystal’s frequency. Since the change in frequency is proportional to the mass of the particulates, the actual weight of the particulates is obtained. This method does not require a K-factor, so no gravimetric sampling is needed. For more details please go through our website https://www.kanomax-usa.com

Dust Monitor , indoor and outdoor applications
Measuring Object

Airborn Particle Matter 0.1 to 2.5 µm

Measuring Range

0.01 to 10 mg/m3

Impactor

2.5 µm

Sampling Flow Rate

1 L/min

Data Logging

500 data and time stamped measurements

Dimensions

H7.0″ x D5.9″ x W2.7″ (180 x 150 x 65mm)

Weight (with batteries)

4.4 lbs. (2 kg)

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

Dust Monitor Model 3521 & 3522 - Kanomax - USA

Kanomax Dust Monitor is the Ideal Oil Mist Detection Tool
The main features are :-

The Kanomax PIEZOBALANCE Dust Monitor 3522  is a unique respirable aerosol monitor, providing direct mass concentration of particulates using PIEZOBALANCE technology; ideal especially for oil mist monitoring.

  • Measures PM 10, Respirable, or PM 2.5 particle matters
  • Real-time measurements of dust concentration
  • Data logging up to 500 measurements
  • Simple cleaning mechanism for easy maintenance
  • Complete with data processing software, RS 232C cable, cleaning kit, Ni-MH battery pack, AC adapter, carrying case and calibration certification.
  • The Kanomax 3521 is equipped with 4 and 10µm impactors while the 3522 is equipped with a 2.5µm impactor.
  •  Unlike conventional dust meters, which count particles, a PIEZOBALANCE dust meter like the 3521 or 3522 “weighs” mass concentration of particulates.
  •  As an air sample enters the system, it travels through the impactor, which captures and removes larger particulates away from the sample.
  • Smaller particulates become electrically charged and deposited on the piezo-crystal.
  • The total mass of the deposited particulates affects the piezo-crystal’s frequency.
  • Since the change in frequency is proportional to the mass of the particulates, the actual weight of the particulates is obtained

The main working principle of Piezobalance dust monitor is when an air sample enters the system, it travels through the impactor, which captures and removes larger particulates away from the sample. Smaller particulates become electrically charged and deposited on the piezo-crystal. The total mass of the deposited particulates affects the piezo-crystal’s frequency. Since the change in frequency is proportional to the mass of the particulates, the actual weight of the particulates is obtained. This method does not require a K-factor, so no gravimetric sampling is needed. For more details please go through our website https://www.kanomax-usa.com

Dust Monitor , indoor and outdoor applications
Measuring Object

Airborn Particle Matter 0.1 to 2.5 µm

Measuring Range

0.01 to 10 mg/m3

Impactor

2.5 µm

Sampling Flow Rate

1 L/min

Data Logging

500 data and time stamped measurements

Dimensions

H7.0″ x D5.9″ x W2.7″ (180 x 150 x 65mm)

Weight (with batteries)

4.4 lbs. (2 kg)