تخطى الى المحتوى

Handheld Particle Counter - Kanomax 3888

رمز التخزين التعريفي : IAQKN3888
يصنع : KANOMAX
نموذج : 3888
ضمان : 1
التوفر : في الأوراق المالية
السعر الأصلي AED 0.00 - السعر الأصلي AED 0.00
السعر الأصلي AED 0.00
AED 10,200.00
AED 10,200.00 - AED 10,200.00
السعر الحالي AED 10,200.00
(بما في ذلك ضريبة القيمة المضافة)

Handheld Particle Counter - Kanomax 3888

Kanomax’s innovative Handheld Particle Counters Models 3888  set the standard of instrumentation in cleanroom / operating room monitoring and verification, filter testing, IAQ investigation, data center cleaning and many more highly specialized and highly sensitive applications. These beautifully engineered devices boast some of the most highly advanced technology in the industry. A combination of accuracy and practicality, these devices count airborne particles with high quality performance.

Features :

  •  Model 3888 displays 3 particle sizes simultaneously (0.3, 0.5, 5.0μm) in cf or m3
  •  Model 3889 displays 6 particle sizes simultaneously (0.3, 0.5, 1.0, 3.0, 5.0, 10.0μm) in cf or m3
  •  Large, 4.3-inch full-color touchscreen
  •  0.3 micron minimum sensitivity
  •  Store up to 10,000 measurements
  •  Compact and Light weight
  •  Remote control software
  •  Easy to read and interpret data due to large screen with full color and graphic display
  •  Storage capacity for up to a week’s worth of data
  •  Compliant with current ISO-14644

Handheld Particle Counter

Sizes

3 channels (0.3, 0.5, 5.0μm

Flow rate

0.1CFM (2.83L/min)
Accuracy: ±5% (Compliant with JIS B9921 and ISO21501-4)

Maximum measurable Concentration

10% for 2,000,000 particles/CF
(compliant with JIS B9921 and ISO21501-4)

Counting efficiency

50±20%(for PSL particles near the minimum measurable size)
100±10%(for PSL particles of 1.5 to 2 times as large as the minimum
measurable size) (Compliant with JIS B9921 and ISO21501-4)

False count

≦1 particle/5 minutes
(Compliant with JIS B9921 and ISO21501-4)

Size resolution

≦15% (for PSL particles near 0.3μm)
(Compliant with JIS B9921 and ISO21501-4)

Display

Communication -Standard USB (Host: for printer and USB flash memory, Device: for PC)
Stand (option)- RS485, Ethernet, and WiFi connection points in the base/stand
Recording media -Media Internal memory
Number and format -Up to 10,000 records in CSV format

Power

Internal supply- Li-ion rechargeable battery (Replaceable)
External supply -AC adaptor Input 100 to 240 V
continuous operation time- 5 hours(Single measurement)

Operating environment

Main body- From 10 to 40 ℃, from 0 to 85%RH (With no condensation)
Probe -From 0 to 50 ℃, from 2 to 98%RH(With no condensation)

Dimension

W213 X H100 X D55 mm

Weight

650g

 

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

Handheld Particle Counter - Kanomax 3888

Kanomax’s innovative Handheld Particle Counters Models 3888  set the standard of instrumentation in cleanroom / operating room monitoring and verification, filter testing, IAQ investigation, data center cleaning and many more highly specialized and highly sensitive applications. These beautifully engineered devices boast some of the most highly advanced technology in the industry. A combination of accuracy and practicality, these devices count airborne particles with high quality performance.

Features :

  •  Model 3888 displays 3 particle sizes simultaneously (0.3, 0.5, 5.0μm) in cf or m3
  •  Model 3889 displays 6 particle sizes simultaneously (0.3, 0.5, 1.0, 3.0, 5.0, 10.0μm) in cf or m3
  •  Large, 4.3-inch full-color touchscreen
  •  0.3 micron minimum sensitivity
  •  Store up to 10,000 measurements
  •  Compact and Light weight
  •  Remote control software
  •  Easy to read and interpret data due to large screen with full color and graphic display
  •  Storage capacity for up to a week’s worth of data
  •  Compliant with current ISO-14644

Handheld Particle Counter

Sizes

3 channels (0.3, 0.5, 5.0μm

Flow rate

0.1CFM (2.83L/min)
Accuracy: ±5% (Compliant with JIS B9921 and ISO21501-4)

Maximum measurable Concentration

10% for 2,000,000 particles/CF
(compliant with JIS B9921 and ISO21501-4)

Counting efficiency

50±20%(for PSL particles near the minimum measurable size)
100±10%(for PSL particles of 1.5 to 2 times as large as the minimum
measurable size) (Compliant with JIS B9921 and ISO21501-4)

False count

≦1 particle/5 minutes
(Compliant with JIS B9921 and ISO21501-4)

Size resolution

≦15% (for PSL particles near 0.3μm)
(Compliant with JIS B9921 and ISO21501-4)

Display

Communication -Standard USB (Host: for printer and USB flash memory, Device: for PC)
Stand (option)- RS485, Ethernet, and WiFi connection points in the base/stand
Recording media -Media Internal memory
Number and format -Up to 10,000 records in CSV format

Power

Internal supply- Li-ion rechargeable battery (Replaceable)
External supply -AC adaptor Input 100 to 240 V
continuous operation time- 5 hours(Single measurement)

Operating environment

Main body- From 10 to 40 ℃, from 0 to 85%RH (With no condensation)
Probe -From 0 to 50 ℃, from 2 to 98%RH(With no condensation)

Dimension

W213 X H100 X D55 mm

Weight

650g

 

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

قارن بين المنتجات

{"one"=>"حدد 2 أو 3 عناصر للمقارنة", "other"=>"تم اختيار {{ count }} من 3 عناصر"}

حدد العنصر الأول للمقارنة

حدد العنصر الثاني للمقارنة

حدد العنصر الثالث للمقارنة

يقارن