SOLAR I-Ve Multifunction I-V Curve Tracer
1500V Multifunction I-V Curve Tracer for maintenance and efficiency tests on single-phase installations.
Measurement of efficiency of a single-phase photovoltaic system
Measurement of I-V Curve of a module or of a string up to 1500V/10A - 1000V/15A
Measurement of open-circuit voltage of a module or of a string (VOC) 1500V
Measurement of short-circuit current of a module or of a string (ISC) 15A
SOLAR I-Ve allows both testing a single-phase (three-phase with optional MPP300) photovoltaic system and verifying I-V curve. Thanks to remote unit SOLAR02, it is possible to test the system complying with the requirement of simultaneity as provided for by the reference standard. SOLAR02 is a datalogger which, synchronized with SOLAR I-Ve, acquires the data relevant to irradiation and temperature while tests carried out by SOLAR I-Ve are carried out.
For measuring I-V curve, SOLAR I-Ve manages an internal database of the modules, which can be updated at any time by the user by comparing the measured data with the rated values, thus allowing the immediate evaluation whether the string or the module fulfills the efficiency parameters declared by the manufacturer. Current and voltage measurement at modules/strings output is measured with the 4-terminal method, which allows extending possible measuring cables without considering any compensation of their resistance, thus obtaining always precise measurements. At the end of the test, the display of I-V curve on the screen is a clear indication about the compliance with the specifications declared by the panel manufacturer.
Detection of I-V curve on PV modules and strings |
128 points |
---|---|
Measuring range of I-V curve / VOC-ISC |
1500V/10A – 1000V/15A |
Quick IVCK test for measuring Voc and Isc on PV modules and strings |
VOC 1500V / ISC 15A |
Single-phase/three-phase photvoltaic systems’ testing |
1MPPT (3MPPT with MPP300) |
Measurement of irradiation with reference cell |
Yes |
Use of remote unit SOLAR-02 with USB \ RF connection |
RF |
Temperature measurement of cell and environment |
Yes |
Active P, Reactive Q, Apparent S Power/Energy |
only active P |
Max number of simultaneously selectable parameters |
9 |
Recording with selectable integration period |
5s-60m |
Indicative memory duration (in days @ PI=10min @ max number of parameters) |
8 |
Summary table of main electric parameters |
Yes |
Measuring range for photovoltaic testing |
1500VDC / 265VAC (Single-Phase) |
Measurement category |
CAT III 300V |
Backlit LCD display |
Yes |
Internal memory capacity |
249 curves I-V 8 days@ PI=10 min |
Provided PC interface with software for Windows |
Yes |
Integrated WiFi connection and compatibility with HTANALYSIS App |
For data download onto the PC\app |
Custom management of internal PV module database |
30 internal, 30.000 on software\app |
Auto power off |
Yes |
Indication of recording duration for photovoltaic testing |
Yes |
Help on line on the display |
Yes |
Size (LxWx H) (mm) |
235x165x75 |
Weight in grams (batteries included) |
1200 |
Guidelines |
CEI 64-8 612.6.2 |
SOLAR I-Ve Multifunction I-V Curve Tracer
1500V Multifunction I-V Curve Tracer for maintenance and efficiency tests on single-phase installations.
Measurement of efficiency of a single-phase photovoltaic system
Measurement of I-V Curve of a module or of a string up to 1500V/10A - 1000V/15A
Measurement of open-circuit voltage of a module or of a string (VOC) 1500V
Measurement of short-circuit current of a module or of a string (ISC) 15A
SOLAR I-Ve allows both testing a single-phase (three-phase with optional MPP300) photovoltaic system and verifying I-V curve. Thanks to remote unit SOLAR02, it is possible to test the system complying with the requirement of simultaneity as provided for by the reference standard. SOLAR02 is a datalogger which, synchronized with SOLAR I-Ve, acquires the data relevant to irradiation and temperature while tests carried out by SOLAR I-Ve are carried out.
For measuring I-V curve, SOLAR I-Ve manages an internal database of the modules, which can be updated at any time by the user by comparing the measured data with the rated values, thus allowing the immediate evaluation whether the string or the module fulfills the efficiency parameters declared by the manufacturer. Current and voltage measurement at modules/strings output is measured with the 4-terminal method, which allows extending possible measuring cables without considering any compensation of their resistance, thus obtaining always precise measurements. At the end of the test, the display of I-V curve on the screen is a clear indication about the compliance with the specifications declared by the panel manufacturer.
Detection of I-V curve on PV modules and strings |
128 points |
---|---|
Measuring range of I-V curve / VOC-ISC |
1500V/10A – 1000V/15A |
Quick IVCK test for measuring Voc and Isc on PV modules and strings |
VOC 1500V / ISC 15A |
Single-phase/three-phase photvoltaic systems’ testing |
1MPPT (3MPPT with MPP300) |
Measurement of irradiation with reference cell |
Yes |
Use of remote unit SOLAR-02 with USB \ RF connection |
RF |
Temperature measurement of cell and environment |
Yes |
Active P, Reactive Q, Apparent S Power/Energy |
only active P |
Max number of simultaneously selectable parameters |
9 |
Recording with selectable integration period |
5s-60m |
Indicative memory duration (in days @ PI=10min @ max number of parameters) |
8 |
Summary table of main electric parameters |
Yes |
Measuring range for photovoltaic testing |
1500VDC / 265VAC (Single-Phase) |
Measurement category |
CAT III 300V |
Backlit LCD display |
Yes |
Internal memory capacity |
249 curves I-V 8 days@ PI=10 min |
Provided PC interface with software for Windows |
Yes |
Integrated WiFi connection and compatibility with HTANALYSIS App |
For data download onto the PC\app |
Custom management of internal PV module database |
30 internal, 30.000 on software\app |
Auto power off |
Yes |
Indication of recording duration for photovoltaic testing |
Yes |
Help on line on the display |
Yes |
Size (LxWx H) (mm) |
235x165x75 |
Weight in grams (batteries included) |
1200 |
Guidelines |
CEI 64-8 612.6.2 |
YOU MAY ALSO LIKE