Circuit Breaker Analyser with Printer 6-Contact CIBRE-60
6-Contact Circuit Breaker Analyser with Built-in Printer
CIBRE-60 Series, 6-Contact Circuit Breaker Analysers are designed using advanced engineering technology to test contact timings of circuit-breakers.
CIBRE-60 Series has fast, easy and accurate measurement features by our user-friendly software.
CIBRE-60 Series is a battery-powered device (optional feature), which allow users to perform tests even without power supply during field tests.
Why do we need to test circuit breakers?
It is very important to test circuit breakers regularly. Contact Timing Tests and Motion tests are performed to determine the optimal performance of the breakers. The testing can determine improper breaker operations in case of system fault and to improve system reliability.
Contact Timing Tests
Contact timing tests are performed to compare the breakers’ main & resistor contact performance against the manufacture’s specifications.
The breakers OPEN, CLOSE, OPEN-CLOSE, CLOSE-OPEN & OPEN-CLOSE-OPEN operations are timed in milliseconds (ms) and cycles and then compared with the manufacturers’ specification to determine the performance of the circuit breaker.
Motion Tests
CIBRE-60 Series can perform motion tests such as Transducer Speed, Stroke and Bounce. Slower transducer speed can reduce the breaking capacity of the main contact while faster speed can cause mechanical damage to the damping components and cause excessive vibration. So, it is necessary to test the transducer speed to compare it with manufacture’s specifications.
CIBRE-60 Series feature with a 7-inch large colour touch display, which is visible under both bright sunlight as well as dim light conditions.
Operators can easily print the measurement results with the 2.28-inch built-in printer of CIBRE-60 Series. The results can also save to a USB flash drive or to the device’s internal memory.
Multi-language capability and user-friendly operation menu make it easy to control CIBRE-60 Series.
CIBRE-60 Series devices are light-weight, compact and rugged with the protection of IP67 (case closed) which makes it perfect for the field test.
Measurement Parameters | Contact Timing (O, C, O-C, C-O & O-C-O), Motion Tests (Transducer Speed, Stroke, Bounce) | |||
Dry Contact Inputs | 6 dry input channels (each detects main) and insertion resistor contacts | |||
Timing Windows | 1s, 10s, 20s | |||
Timing Resolution | 1 s duration | 10 s duration | 20 s duration | |
± 50 µs | ± 500 µs | ± 1 ms | ||
Timing Accuracy | 0.05% rdg ± 0.1 ms | |||
Dry contact channel protection | Fuses and Diodes protection, All contacts grounded until test | |||
Contact detection range | Closed | ≤20 Ω | ||
Open | ≥5000 Ω | |||
Resistor detection range | 20Ω – 5000Ω | |||
Trigger input voltage | 24 – 300 V DC or ACpeak | |||
Dry contact input protection | Diode Protection/ ESD | |||
Breaker Operations | OPEN, CLOSE, OPEN-CLOSE, CLOSE-OPEN, OPEN-CLOSE-OPEN | |||
Voltage sensing input range | V1 (Analogue Input) | V2 (Presence/Absence Detector) | ||
0 – 250 V DC or ACpeak | 24 – 300 V DC or ACpeak | |||
Breaker Initiate Capacity | 20 A, 300 V DC or ACpeak | |||
Digital Travel Transducer Input | 5V/12Vdc TTL | |||
Initiate current reading range | 0 – 20A DC, 5 kHz | |||
Input Power | 100-240 V, 47/63 Hz | |||
Battery | Yes, 14.4 Vdc 6.9 Ah (Optional; Model: CIBRE-60B, CIBRE-60B BLUE) | |||
Display | 7-inch Colour Touch Display | |||
Memory | Up to 200 records | |||
Communication | USB 2.0/1.1 Standard-A, USB 2.0/1.1 Standard-B
Bluetooth (Factory install option; Model: CIBRE-60 BLUE, CIBRE-60B BLUE) |
|||
Printer | 2.28-inch Built-in Printer | |||
Dimensions | 16.9″ x 12.9″ x 9.3” (429 mm x 328 mm x 236 mm) | |||
Weight | 8.2 kg (models with battery) | |||
Working Temperature | -10 °C to +60 °C | |||
Humidity | 90% RH non-condensing | |||
Protection Class | IP67 (case closed) | |||
Standard Supply | CIBRE-60, 20 ft. Contact Cable, 33 ft. Contact Extension Cable, 3 ft. Initiate Cable, 20 ft. Initiate Extension Cable, 3 ft. External Trigger Cable, 20 ft. External Trigger Extension Cable, 5 ft. Voltage Measurement Cable, 20 ft. Voltage Measurement Extension Cable, Power Cable, Ground Cable, USB Cable, Printer Paper (x2), USB flash drive, Instruction Manual (Soft Copy), Cable Bag | |||
Options | 325 mm Linear Encoder, Rotary Encoder, Battery, Bluetooth | |||
Ordering Information | CIBRE-60, 6-Contact Circuit Breaker Analyser with Built-in Printer | |||
CIBRE-60 BLUE, 6-Contact Circuit Breaker Analyser with Built-in Bluetooth & Printer | ||||
CIBRE-60B, 6-Contact Circuit Breaker Analyser with Built-in Battery & Printer | ||||
CIBRE-60B BLUE, 6-Contact Circuit Breaker Analyser with Built-in Battery, Bluetooth & Printer |
Circuit Breaker Analyser with Printer 6-Contact CIBRE-60
6-Contact Circuit Breaker Analyser with Built-in Printer
CIBRE-60 Series, 6-Contact Circuit Breaker Analysers are designed using advanced engineering technology to test contact timings of circuit-breakers.
CIBRE-60 Series has fast, easy and accurate measurement features by our user-friendly software.
CIBRE-60 Series is a battery-powered device (optional feature), which allow users to perform tests even without power supply during field tests.
Why do we need to test circuit breakers?
It is very important to test circuit breakers regularly. Contact Timing Tests and Motion tests are performed to determine the optimal performance of the breakers. The testing can determine improper breaker operations in case of system fault and to improve system reliability.
Contact Timing Tests
Contact timing tests are performed to compare the breakers’ main & resistor contact performance against the manufacture’s specifications.
The breakers OPEN, CLOSE, OPEN-CLOSE, CLOSE-OPEN & OPEN-CLOSE-OPEN operations are timed in milliseconds (ms) and cycles and then compared with the manufacturers’ specification to determine the performance of the circuit breaker.
Motion Tests
CIBRE-60 Series can perform motion tests such as Transducer Speed, Stroke and Bounce. Slower transducer speed can reduce the breaking capacity of the main contact while faster speed can cause mechanical damage to the damping components and cause excessive vibration. So, it is necessary to test the transducer speed to compare it with manufacture’s specifications.
CIBRE-60 Series feature with a 7-inch large colour touch display, which is visible under both bright sunlight as well as dim light conditions.
Operators can easily print the measurement results with the 2.28-inch built-in printer of CIBRE-60 Series. The results can also save to a USB flash drive or to the device’s internal memory.
Multi-language capability and user-friendly operation menu make it easy to control CIBRE-60 Series.
CIBRE-60 Series devices are light-weight, compact and rugged with the protection of IP67 (case closed) which makes it perfect for the field test.
Measurement Parameters | Contact Timing (O, C, O-C, C-O & O-C-O), Motion Tests (Transducer Speed, Stroke, Bounce) | |||
Dry Contact Inputs | 6 dry input channels (each detects main) and insertion resistor contacts | |||
Timing Windows | 1s, 10s, 20s | |||
Timing Resolution | 1 s duration | 10 s duration | 20 s duration | |
± 50 µs | ± 500 µs | ± 1 ms | ||
Timing Accuracy | 0.05% rdg ± 0.1 ms | |||
Dry contact channel protection | Fuses and Diodes protection, All contacts grounded until test | |||
Contact detection range | Closed | ≤20 Ω | ||
Open | ≥5000 Ω | |||
Resistor detection range | 20Ω – 5000Ω | |||
Trigger input voltage | 24 – 300 V DC or ACpeak | |||
Dry contact input protection | Diode Protection/ ESD | |||
Breaker Operations | OPEN, CLOSE, OPEN-CLOSE, CLOSE-OPEN, OPEN-CLOSE-OPEN | |||
Voltage sensing input range | V1 (Analogue Input) | V2 (Presence/Absence Detector) | ||
0 – 250 V DC or ACpeak | 24 – 300 V DC or ACpeak | |||
Breaker Initiate Capacity | 20 A, 300 V DC or ACpeak | |||
Digital Travel Transducer Input | 5V/12Vdc TTL | |||
Initiate current reading range | 0 – 20A DC, 5 kHz | |||
Input Power | 100-240 V, 47/63 Hz | |||
Battery | Yes, 14.4 Vdc 6.9 Ah (Optional; Model: CIBRE-60B, CIBRE-60B BLUE) | |||
Display | 7-inch Colour Touch Display | |||
Memory | Up to 200 records | |||
Communication | USB 2.0/1.1 Standard-A, USB 2.0/1.1 Standard-B
Bluetooth (Factory install option; Model: CIBRE-60 BLUE, CIBRE-60B BLUE) |
|||
Printer | 2.28-inch Built-in Printer | |||
Dimensions | 16.9″ x 12.9″ x 9.3” (429 mm x 328 mm x 236 mm) | |||
Weight | 8.2 kg (models with battery) | |||
Working Temperature | -10 °C to +60 °C | |||
Humidity | 90% RH non-condensing | |||
Protection Class | IP67 (case closed) | |||
Standard Supply | CIBRE-60, 20 ft. Contact Cable, 33 ft. Contact Extension Cable, 3 ft. Initiate Cable, 20 ft. Initiate Extension Cable, 3 ft. External Trigger Cable, 20 ft. External Trigger Extension Cable, 5 ft. Voltage Measurement Cable, 20 ft. Voltage Measurement Extension Cable, Power Cable, Ground Cable, USB Cable, Printer Paper (x2), USB flash drive, Instruction Manual (Soft Copy), Cable Bag | |||
Options | 325 mm Linear Encoder, Rotary Encoder, Battery, Bluetooth | |||
Ordering Information | CIBRE-60, 6-Contact Circuit Breaker Analyser with Built-in Printer | |||
CIBRE-60 BLUE, 6-Contact Circuit Breaker Analyser with Built-in Bluetooth & Printer | ||||
CIBRE-60B, 6-Contact Circuit Breaker Analyser with Built-in Battery & Printer | ||||
CIBRE-60B BLUE, 6-Contact Circuit Breaker Analyser with Built-in Battery, Bluetooth & Printer |
YOU MAY ALSO LIKE