Process Calibrator Meatest M160 Precision DC Calibrator
20 ppm calibrator of DC process signals designed for calibration of evaluation units and process multimeters under demanding industrial conditions. Includes RTD and resistance source.
- 20 ppm accuracy
- 13°C - 33°C reference temp. range
- 100 V @ 25 mA output capacity
Precision DC calibrator M160 is a portable source of industrial process signals for calibration of multimeters in laboratories as well as on site calibration of evaluation units and other process meters. High load capacity of both voltage and current outputs, robust design and exceptional 20 ppm accuracy over 20°C-wide reference temperature range make this calibrator great for demanding conditions in production facilities. Other functions include thermocouple and RTD simulation, resistance and frequency, all with accuracy and resolution to meet all requirements. With option 91 the calibrator can measure temperature directly at output terminals and compensate the cold junction effect.
User comfort
Beside M160's industrial versatility, the calibrator is focused on user friendliness making calibrations simple and straightforward. Main parameters of both generated and measured signals are displayed on large LCD together with function-specific tooltip, providing all relevant details including range, accuracy or load limit. Inspired by recalibration simplicity of M6xx series, the M160 can be easily calibrated using just its front keyboard without any mechanical adjustment inside the instrument.
M160 can be connected to various ATE systems via RS232, USB, LAN or GPIB interface and is fully compatible with WinQbase/Caliber calibration software including the CamOCR module for automated optical UUT readouts.
DC voltage | 0 - 100 V, max. burden up to 2.5 W ± 20 ppm / year |
DC current | 0 - 50 mA, max. burden up to 2.5 W ± 50 ppm / year |
Resistance | 10 Ω - 300 kΩ, resolution from 100 μΩ ± 200 ppm / year |
Temperature | TC BCDEG2JKMNRST with cold junction compensation RTD ± 0.1°C / year |
Frequency | 0.01 Hz - 15 kHz ± 50 ppm / year |
Process Meter
Frequency | 0.01 Hz - 100 kHz ± 50 ppm / year |
Process Calibrator Meatest M160 Precision DC Calibrator
20 ppm calibrator of DC process signals designed for calibration of evaluation units and process multimeters under demanding industrial conditions. Includes RTD and resistance source.
- 20 ppm accuracy
- 13°C - 33°C reference temp. range
- 100 V @ 25 mA output capacity
Precision DC calibrator M160 is a portable source of industrial process signals for calibration of multimeters in laboratories as well as on site calibration of evaluation units and other process meters. High load capacity of both voltage and current outputs, robust design and exceptional 20 ppm accuracy over 20°C-wide reference temperature range make this calibrator great for demanding conditions in production facilities. Other functions include thermocouple and RTD simulation, resistance and frequency, all with accuracy and resolution to meet all requirements. With option 91 the calibrator can measure temperature directly at output terminals and compensate the cold junction effect.
User comfort
Beside M160's industrial versatility, the calibrator is focused on user friendliness making calibrations simple and straightforward. Main parameters of both generated and measured signals are displayed on large LCD together with function-specific tooltip, providing all relevant details including range, accuracy or load limit. Inspired by recalibration simplicity of M6xx series, the M160 can be easily calibrated using just its front keyboard without any mechanical adjustment inside the instrument.
M160 can be connected to various ATE systems via RS232, USB, LAN or GPIB interface and is fully compatible with WinQbase/Caliber calibration software including the CamOCR module for automated optical UUT readouts.
DC voltage | 0 - 100 V, max. burden up to 2.5 W ± 20 ppm / year |
DC current | 0 - 50 mA, max. burden up to 2.5 W ± 50 ppm / year |
Resistance | 10 Ω - 300 kΩ, resolution from 100 μΩ ± 200 ppm / year |
Temperature | TC BCDEG2JKMNRST with cold junction compensation RTD ± 0.1°C / year |
Frequency | 0.01 Hz - 15 kHz ± 50 ppm / year |
Process Meter
Frequency | 0.01 Hz - 100 kHz ± 50 ppm / year |
YOU MAY ALSO LIKE