RTD and Thermocouple Calibrator PIE 525B
With the PIE 525B you can check and calibrate all your thermocouple and RTD instruments, and measure temperature sensors.
Carry it without worry - it comes protected with a rubber boot and rugged, low profile switches. Easy to operate even in the dark areas of
the plant with the backlit display.The PIE 525B works with the thermocouples you use including types J, K, T, E, R, S, B, N, G, C, D, L (J-DIN), U (T-DIN) and P (Platinel II). Or calibrate from -13.0000 to +80.0000 mV
-
Calibrate T/C instruments to 0.1 & 0.01 °F & °C
Types J, K, T, E, R, S, B, N, G, C, D, L (J DIN), U (T DIN) & P (Platinel): -13.000 to 80.000 mV -
Calibrate RTD instruments to 0.1 & 0.01 °F & °C
Pt 10, 50, 100, 200, 500 & 1000 Ohm (3850)
Pt 100 Ohm (alpha=3902, 3916, 3926)
Cu 10 & 50 Ohm and Ni 120 Ohm -
Calibrate with Confidence
Resolution to 0.01 °F & °C; accurate to 0.2°
Cold Junction Sensor accurate to 0.05°C -
Verify Heat Treating Uniformity Survey Recorders and perform System Accuracy Tests
The PIE 525B is capable of meeting the requirements of an AMS 2750 Field Test Instrument when certified by an accredited laboratory. -
Troubleshoot RTD Sensors & Instruments
Automatic detection of 2, 3 or 4 wire connections indicates when individual wire connections are open. Verify proper instrument operation by measuring the excitation current. -
Faster Calibrations
Instantly select three outputs with EZ-CHECK switch
Easily find trip points with two speed EZ-DIAL knob & Automatic Stepping -
Easily Change T/C and RTD Types & Scale
Double click to select T/C or RTD type & °F & °C
RTD and Thermocouple Calibrator PIE 525B
With the PIE 525B you can check and calibrate all your thermocouple and RTD instruments, and measure temperature sensors.
Carry it without worry - it comes protected with a rubber boot and rugged, low profile switches. Easy to operate even in the dark areas of
the plant with the backlit display.The PIE 525B works with the thermocouples you use including types J, K, T, E, R, S, B, N, G, C, D, L (J-DIN), U (T-DIN) and P (Platinel II). Or calibrate from -13.0000 to +80.0000 mV
-
Calibrate T/C instruments to 0.1 & 0.01 °F & °C
Types J, K, T, E, R, S, B, N, G, C, D, L (J DIN), U (T DIN) & P (Platinel): -13.000 to 80.000 mV -
Calibrate RTD instruments to 0.1 & 0.01 °F & °C
Pt 10, 50, 100, 200, 500 & 1000 Ohm (3850)
Pt 100 Ohm (alpha=3902, 3916, 3926)
Cu 10 & 50 Ohm and Ni 120 Ohm -
Calibrate with Confidence
Resolution to 0.01 °F & °C; accurate to 0.2°
Cold Junction Sensor accurate to 0.05°C -
Verify Heat Treating Uniformity Survey Recorders and perform System Accuracy Tests
The PIE 525B is capable of meeting the requirements of an AMS 2750 Field Test Instrument when certified by an accredited laboratory. -
Troubleshoot RTD Sensors & Instruments
Automatic detection of 2, 3 or 4 wire connections indicates when individual wire connections are open. Verify proper instrument operation by measuring the excitation current. -
Faster Calibrations
Instantly select three outputs with EZ-CHECK switch
Easily find trip points with two speed EZ-DIAL knob & Automatic Stepping -
Easily Change T/C and RTD Types & Scale
Double click to select T/C or RTD type & °F & °C
YOU MAY ALSO LIKE