Skip to content

Aerosol Photometer Model 3991 – Advanced HEPA Filter Leak Detection & Validation Device

SKU : GTI3991
MAKE : GTI
MODEL : 3991
WARRANTY : 1 Year
Original price AED 0
Original price $11,436.35 - Original price $11,436.35
Original price
Current price AED 42,000.00
$11,436.35 - $11,436.35
Current price $11,436.35

Aerosol Photometer Model 3991 – Advanced HEPA Filter Leak Detection & Validation Device

The Aerosol Photometer Model 3991 is an advanced digital instrument engineered for HEPA filter leak detection, ULPA integrity testing, and cleanroom validation. Designed for professionals in pharmaceutical cleanrooms, biosafety cabinets, and nuclear facilities, this high-performance aerosol photometer combines portability, precision, and durability in one.

Equipped with a vibrant 8.4-inch LCD touchscreen, this aerosol concentration detector features a built-in thermal printer, infrared scanning probe, lithium battery power, and intelligent GMP Three-Level Privileged Management. It provides unmatched traceability, large data storage, and stable testing in all controlled environments.

Ideal for air filtration system testing, pharmaceutical facility compliance, and biosafety cabinet performance validation, the Model 3991 is your go-to solution for industry-grade HEPA filter inspection.

Key Features

  • 8.4-inch color touch screen with English & Chinese interface

  • Real-time data printing with built-in thermal printer

  • One-dimensional barcode scanning probe with auto traceability

  • Stores up to 100,000 sets of data with USB data export

  • GMP Three-Level Privileged Management with login permissions

  • Lithium battery-powered (up to 4.5 hours of continuous testing)

  • Built-in low-power mode for energy efficiency

  • Advanced noise suppression for stable aerosol concentration readings

  • Compatible with DOP, PAO, Ondina, PEG, and more

  • Compact and portable for easy field use

 

Data Accuracy

 0.0001–100.0%, 8.4-inch Touch LCD Screen

 

Dynamic Range

 0.0001 µg/L–600 µg/L

 

Accuracy

 ±1% of readings (0.01–100%)

 

Repeatability

 ±0.5% of readings (0.01–100%)

 

Flow Control

 1 cfm (28.3 L/min) ±5%

 

Zero Building

 Automatic or Manual

 

Alarm Modes

 Audible, Visual, Vibratory

 

Power-Saving Mode

 Yes

 

Reporting Modes

 Continuous, Summary, Monitoring

 

Printer

 Built-in thermal printer

 

ID Encoding

 Barcode scanning for data classification

 

Data Output

 USB, Storage, Print

 

Data Storage Capacity

 100,000 sets

 

Communication

 USB to PC, continuous scanning testing

 

Language Support

 English

 

Reagents Supported

 PAO, DOP, Ondina, Polyethylene Glycol, Corn Oil, Mineral Oil, Paraffin Oil

 

Sampling Port

 Standard internal rectangular port

 

Shell Material

 SUS304 Stainless Steel

 

Temperature & Humidity

 5–50°C, 5–95% RH (non-condensing

 

Storage Temperature

 -20°C to 60°C (RH < 95%)

 

Power Supply

 AC100–240V 50/60Hz or built-in lithium battery

 

Dimensions

 Approx. 220 × 260 × 390 mm

 

Weight

 11.1 kg (unit), 1 kg (probe and accessories)

 

Certifications

 NSF49, IEST, ISO14644

 

EN61010-1

2010

 

EN61326

2006

 

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

What is the Aerosol Photometer Model 3991 used for?

The Model 3991 is used for HEPA and ULPA filter integrity testing, cleanroom validation, and air filtration system performance testing.

How does the built-in printer benefit users?

The built-in thermal printer allows users to instantly print testing results, ensuring proper documentation and audit-ready records.

Can this device be used in the field?

Yes, it is powered by a built-in lithium battery that lasts up to 4.5 hours, making it ideal for portable HEPA filter inspection tasks.

What are the data management capabilities?

The unit stores up to 100,000 sets of test data and offers USB connectivity for exporting and analyzing results on a computer.

Does the scanning probe support barcode tracking?

Yes, the scanning probe has a one-dimensional barcode reader to automatically classify and trace data for improved testing efficiency.

Which industries use this device most?

Pharmaceutical cleanrooms, nuclear facilities, biosafety cabinets, fume hoods, and medical institutions rely on this photometer for compliance testing.

Aerosol Photometer Model 3991 – Advanced HEPA Filter Leak Detection & Validation Device

The Aerosol Photometer Model 3991 is an advanced digital instrument engineered for HEPA filter leak detection, ULPA integrity testing, and cleanroom validation. Designed for professionals in pharmaceutical cleanrooms, biosafety cabinets, and nuclear facilities, this high-performance aerosol photometer combines portability, precision, and durability in one.

Equipped with a vibrant 8.4-inch LCD touchscreen, this aerosol concentration detector features a built-in thermal printer, infrared scanning probe, lithium battery power, and intelligent GMP Three-Level Privileged Management. It provides unmatched traceability, large data storage, and stable testing in all controlled environments.

Ideal for air filtration system testing, pharmaceutical facility compliance, and biosafety cabinet performance validation, the Model 3991 is your go-to solution for industry-grade HEPA filter inspection.

Key Features

  • 8.4-inch color touch screen with English & Chinese interface

  • Real-time data printing with built-in thermal printer

  • One-dimensional barcode scanning probe with auto traceability

  • Stores up to 100,000 sets of data with USB data export

  • GMP Three-Level Privileged Management with login permissions

  • Lithium battery-powered (up to 4.5 hours of continuous testing)

  • Built-in low-power mode for energy efficiency

  • Advanced noise suppression for stable aerosol concentration readings

  • Compatible with DOP, PAO, Ondina, PEG, and more

  • Compact and portable for easy field use

 

Data Accuracy

 0.0001–100.0%, 8.4-inch Touch LCD Screen

 

Dynamic Range

 0.0001 µg/L–600 µg/L

 

Accuracy

 ±1% of readings (0.01–100%)

 

Repeatability

 ±0.5% of readings (0.01–100%)

 

Flow Control

 1 cfm (28.3 L/min) ±5%

 

Zero Building

 Automatic or Manual

 

Alarm Modes

 Audible, Visual, Vibratory

 

Power-Saving Mode

 Yes

 

Reporting Modes

 Continuous, Summary, Monitoring

 

Printer

 Built-in thermal printer

 

ID Encoding

 Barcode scanning for data classification

 

Data Output

 USB, Storage, Print

 

Data Storage Capacity

 100,000 sets

 

Communication

 USB to PC, continuous scanning testing

 

Language Support

 English

 

Reagents Supported

 PAO, DOP, Ondina, Polyethylene Glycol, Corn Oil, Mineral Oil, Paraffin Oil

 

Sampling Port

 Standard internal rectangular port

 

Shell Material

 SUS304 Stainless Steel

 

Temperature & Humidity

 5–50°C, 5–95% RH (non-condensing

 

Storage Temperature

 -20°C to 60°C (RH < 95%)

 

Power Supply

 AC100–240V 50/60Hz or built-in lithium battery

 

Dimensions

 Approx. 220 × 260 × 390 mm

 

Weight

 11.1 kg (unit), 1 kg (probe and accessories)

 

Certifications

 NSF49, IEST, ISO14644

 

EN61010-1

2010

 

EN61326

2006

 

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

What is the Aerosol Photometer Model 3991 used for?

The Model 3991 is used for HEPA and ULPA filter integrity testing, cleanroom validation, and air filtration system performance testing.

How does the built-in printer benefit users?

The built-in thermal printer allows users to instantly print testing results, ensuring proper documentation and audit-ready records.

Can this device be used in the field?

Yes, it is powered by a built-in lithium battery that lasts up to 4.5 hours, making it ideal for portable HEPA filter inspection tasks.

What are the data management capabilities?

The unit stores up to 100,000 sets of test data and offers USB connectivity for exporting and analyzing results on a computer.

Does the scanning probe support barcode tracking?

Yes, the scanning probe has a one-dimensional barcode reader to automatically classify and trace data for improved testing efficiency.

Which industries use this device most?

Pharmaceutical cleanrooms, nuclear facilities, biosafety cabinets, fume hoods, and medical institutions rely on this photometer for compliance testing.

Compare products

0 of 3 items selected

Select first item to compare

Select second item to compare

Select third item to compare

Compare
My Wishlist0
AED