cGas Analog Detector for Indoor Public Spaces Carbon Monoxide Sensor and Carbon Dioxide Sensor

MAKE : CRITICAL ENVIRONMENT TECHNOLOGIES
MODEL : CGAS-DP-CO-CO2-5K
WARRANTY : 1 Year
AVAILABILITY : IN STOCK
Original price AED 3,200.00 - Original price AED 3,200.00
Original price
AED 3,200.00
AED 3,200.00 - AED 3,200.00
Current price AED 3,200.00
(Including VAT)

cGas Analog Detector for Indoor Public Spaces Carbon Monoxide Sensor and Carbon Dioxide Sensor

This cGas Detector is designed for use in publicly occupied spaces where integrated demand-controlled ventilation (DCV) is used for air quality and energy savings; for continuous monitoring of refrigerants where high-efficiency, high volume refrigerant cooling and heating systems (VRF) are used to keep the indoor environment comfortable; and for other continuous monitoring of hazardous gases in publicly frequented areas. The low profile, aesthetically pleasing enclosure is designed to reduce the noticeability of the device by the public eye.

Both the analog and digital models are powered by 24 VDC or ground referenced AC, come with an LCD display, temperature compensation and thermal resetting fuse. Sensor replacement is easy with true Plug & Play smart sensors that arrive pre-calibrated. The firmware and configuration can be upgraded in the field using the USB connection.

The digital models are user configurable in the field for BACnet® MS-TP RS-485 or Modbus® RTU RS-485 output for communicating with a controller, Building Automation System or other control panel.

Both the analog and digital models may be configured with an internal gas sensor or a remote refrigerant sensor (dongle). The internal sensor model is ideal for vertical terminal air conditioner (VTAC) systems. The remote refrigerant sensor model has a 9m / 29.5ft dongle cable that is ideal for use in packaged terminal air conditioner (PTAC) applications.

  • Key Features

    • Analog models have one 4-20 mA analog output or 0-10 volt or 2-10 volt output
    • Digital models have user in the field configurable BACnet® MS/TP RS-485 or Modbus® RTU RS-485 digital output signal to a BAS
    • Easy Plug & Play Smart Sensor replacement at end of life
    • Pre-calibrated replacement sensors
    • Bright LCD display with configurable visual alarm
    • 1 SPDT dry contact relay, rated 30 volts, 2 amps max with or without internal buzzer*
    • Models available with user selectable 1PM, 2.5PM or 10PM particulate sensor
    • Optional RH & Temperature sensor (Option -RHT)
    • Low profile to reduce noticeability in public spaces
    • USB port for configuration changes and firmware upgrades
    • RoHS compliant circuit boards
  • Applications

    • Hotels
    • Office Buildings
    • Hospitals
    • Apartment Buildings
    • Retirement Homes
    • Theatres / Auditoriums
    • Schools / Universities / Dormitories
Enclosure

 White polycarbonate, low-profile design.

 

Weight

 400 g (14 oz)

 

Size

 124.9 x 124.9 x 50.0 mm (4.9 x 4.9 x 2.0 inches)

 

Power Requirement

 16-30 VDC, 3W; 12-27 VAC, 50-60 Hz, 3 VA

 

Operating Temperature

 0°C to 40°C (32°F to 104°F)

 

Operating Humidity

 15% - 90% RH non-condensing

 

Analog Output

 One 4-20 mA output or jumper-selectable 0-10 V output.

 

Relay & Buzzer

 1 SPDT relay rated 30 volts, 2 amps, with an internal buzzer rated 90 dB @ 10 cm.

 

Certifications

 Conforms to CSA-C22.2 No. 205-12, UL508, EMC Directive 2014/30/EU, EN 50270, 2015.

 

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

How does the cGas Analog Detector integrate with building management systems?

The detector offers a 4-20 mA analog output or selectable 0-10 V output, making it compatible with most building automation and ventilation control systems.

Can I replace the sensors easily?

Yes, the cGas Detector features plug-and-play, pre-calibrated sensors that can be quickly replaced, ensuring minimal downtime.

Does the detector provide real-time monitoring of both CO and CO2 levels?

Yes, the built-in LCD display provides real-time readings of both carbon monoxide and carbon dioxide levels for continuous air quality assessment.

What power supply is required for this detector?

The device operates on 16-30 VDC or 12-27 VAC, making it adaptable to a variety of installation environments.

Can this detector monitor both temperature and humidity?

Yes, an optional RH & Temperature sensor (Option -RHT) can be added to monitor relative humidity and temperature alongside CO and CO2 levels.

Is the cGas Analog Detector suitable for use in environments like schools and hospitals?

Yes, its low-profile design and dual gas detection capabilities make it an ideal choice for sensitive environments such as schools, hospitals, office buildings, and public venues.

cGas Analog Detector for Indoor Public Spaces Carbon Monoxide Sensor and Carbon Dioxide Sensor

This cGas Detector is designed for use in publicly occupied spaces where integrated demand-controlled ventilation (DCV) is used for air quality and energy savings; for continuous monitoring of refrigerants where high-efficiency, high volume refrigerant cooling and heating systems (VRF) are used to keep the indoor environment comfortable; and for other continuous monitoring of hazardous gases in publicly frequented areas. The low profile, aesthetically pleasing enclosure is designed to reduce the noticeability of the device by the public eye.

Both the analog and digital models are powered by 24 VDC or ground referenced AC, come with an LCD display, temperature compensation and thermal resetting fuse. Sensor replacement is easy with true Plug & Play smart sensors that arrive pre-calibrated. The firmware and configuration can be upgraded in the field using the USB connection.

The digital models are user configurable in the field for BACnet® MS-TP RS-485 or Modbus® RTU RS-485 output for communicating with a controller, Building Automation System or other control panel.

Both the analog and digital models may be configured with an internal gas sensor or a remote refrigerant sensor (dongle). The internal sensor model is ideal for vertical terminal air conditioner (VTAC) systems. The remote refrigerant sensor model has a 9m / 29.5ft dongle cable that is ideal for use in packaged terminal air conditioner (PTAC) applications.

  • Key Features

    • Analog models have one 4-20 mA analog output or 0-10 volt or 2-10 volt output
    • Digital models have user in the field configurable BACnet® MS/TP RS-485 or Modbus® RTU RS-485 digital output signal to a BAS
    • Easy Plug & Play Smart Sensor replacement at end of life
    • Pre-calibrated replacement sensors
    • Bright LCD display with configurable visual alarm
    • 1 SPDT dry contact relay, rated 30 volts, 2 amps max with or without internal buzzer*
    • Models available with user selectable 1PM, 2.5PM or 10PM particulate sensor
    • Optional RH & Temperature sensor (Option -RHT)
    • Low profile to reduce noticeability in public spaces
    • USB port for configuration changes and firmware upgrades
    • RoHS compliant circuit boards
  • Applications

    • Hotels
    • Office Buildings
    • Hospitals
    • Apartment Buildings
    • Retirement Homes
    • Theatres / Auditoriums
    • Schools / Universities / Dormitories
Enclosure

 White polycarbonate, low-profile design.

 

Weight

 400 g (14 oz)

 

Size

 124.9 x 124.9 x 50.0 mm (4.9 x 4.9 x 2.0 inches)

 

Power Requirement

 16-30 VDC, 3W; 12-27 VAC, 50-60 Hz, 3 VA

 

Operating Temperature

 0°C to 40°C (32°F to 104°F)

 

Operating Humidity

 15% - 90% RH non-condensing

 

Analog Output

 One 4-20 mA output or jumper-selectable 0-10 V output.

 

Relay & Buzzer

 1 SPDT relay rated 30 volts, 2 amps, with an internal buzzer rated 90 dB @ 10 cm.

 

Certifications

 Conforms to CSA-C22.2 No. 205-12, UL508, EMC Directive 2014/30/EU, EN 50270, 2015.

 

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

How does the cGas Analog Detector integrate with building management systems?

The detector offers a 4-20 mA analog output or selectable 0-10 V output, making it compatible with most building automation and ventilation control systems.

Can I replace the sensors easily?

Yes, the cGas Detector features plug-and-play, pre-calibrated sensors that can be quickly replaced, ensuring minimal downtime.

Does the detector provide real-time monitoring of both CO and CO2 levels?

Yes, the built-in LCD display provides real-time readings of both carbon monoxide and carbon dioxide levels for continuous air quality assessment.

What power supply is required for this detector?

The device operates on 16-30 VDC or 12-27 VAC, making it adaptable to a variety of installation environments.

Can this detector monitor both temperature and humidity?

Yes, an optional RH & Temperature sensor (Option -RHT) can be added to monitor relative humidity and temperature alongside CO and CO2 levels.

Is the cGas Analog Detector suitable for use in environments like schools and hospitals?

Yes, its low-profile design and dual gas detection capabilities make it an ideal choice for sensitive environments such as schools, hospitals, office buildings, and public venues.

Compare products

{"one"=>"Select 2 or 3 items to compare", "other"=>"{{ count }} of 3 items selected"}

Select first item to compare

Select second item to compare

Select third item to compare

Compare