GSC60 was designed with the aim of making safety of electrical installations visible and valuable, easily and quickly.Thanks to the new HTOS™ system the unit displays a message OK – NOT OK after completing the test.The user interface, totally updated under HTOS™, permits to set and carry out measurements in few steps.You can store all recorded data and create folders and subfolders for each kind of test adding comments and notes by means of virtual keyboard.GSC60 is also a three-phase power and energy consumption analyzer boasting, as unique feature, its FREE APP HTAnalysis compatible with iOS and Android.Test results can be transferred through Wi-Fi onto smartphone or tablet enclosing a picture, a video or a voice note to each measurement. You can transfer everything onto HT Cloud and make data available in real time for your colleagues all over the world.GSC60 makes the job of installer, electrician or consultant easy, rapid and cost-effective.

Electrical Safety Tests and Power Quality analysis
Touchscreen colour display

Yes

Integrated WiFi connection and compatibility with HTANALYSIS App

Yes

Continuity of protective circuit with 200mA

Yes

Insulation with voltage 50, 100, 250, 500, 1000VDC

Yes

Time/Current tripping of A, AC General, Selective and Delayed RCDs up to 1000mA

Yes

Time/Current tripping of type B RCDs up to 300mA

Yes

Tripping time and current of RCDs with separate clamp jaws type B, A, AC Standard, Selective and Delayed up to 10A

Yes

Loop impedance P-N, P-P, P-PE and calculation of prospective short-circuit current

Yes

Line/Loop impedance with high resolution (with optional accessory IMP57)

Yes

Percentage voltage drop on the line

Yes

Measurement and recording of leakage currents and environment parameters

Yes

Three-phase Power quality and Energy consumption analysis:

Yes

9 types of electrical systems

1Φ-2wires, 1Φ-split phase, 3Φ-3 wires, 3Φ-Aron, 3Φ-Open Δ, 3Φ-Open Y, 3Φ-2 el. 1/2, 3Φ-4 wires Y, 3Φ-High Leg.

632 parameters can be recorded for over two months

Yes

Voltage Anomalies (dips and peaks) with a resolution of 20ms

@50Hz

Measurement/recording of Active, Reactive, Apparent Power

Yes

Measurement/recording of Active, Reactive, Apparent Energy

Yes

Measurement/recording of Cosphi, Power Factor

Yes

Measurement/Recording of Voltage and Current Harmonics up to 49th with THD%

Yes

Voltage/current vector diagram

Yes

Voltage/current waveforms

Yes

Tables or histograms of Harmonics and THD%

Yes

Summary table of main electric parameters

Yes

Help on line on the display

Yes

Protection category

CAT IV

Guidelines

EMC: IEC/EN61326
EN50160
EN50522
EN60909-0
EN61936-1
IEC/EN61010-031
IEC/EN61010-1
IEC/EN61010-2-032
IEC/EN61187
IEC/EN61557-1
IEC/EN61557-10
IEC/EN61557-2
IEC/EN61557-3
IEC/EN61557-4
IEC/EN61557-5
IEC/EN61557-6
IEC/EN61557-7
UNE20460

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

GSC60 Electrical Safety Tests and Power Quality analysis

One instrument for all electrical safety tests and Power Quality analysis

GSC60 was designed with the aim of making safety of electrical installations visible and valuable, easily and quickly.Thanks to the new HTOS™ system the unit displays a message OK – NOT OK after completing the test.The user interface, totally updated under HTOS™, permits to set and carry out measurements in few steps.You can store all recorded data and create folders and subfolders for each kind of test adding comments and notes by means of virtual keyboard.GSC60 is also a three-phase power and energy consumption analyzer boasting, as unique feature, its FREE APP HTAnalysis compatible with iOS and Android.Test results can be transferred through Wi-Fi onto smartphone or tablet enclosing a picture, a video or a voice note to each measurement. You can transfer everything onto HT Cloud and make data available in real time for your colleagues all over the world.GSC60 makes the job of installer, electrician or consultant easy, rapid and cost-effective.

Electrical Safety Tests and Power Quality analysis
Touchscreen colour display

Yes

Integrated WiFi connection and compatibility with HTANALYSIS App

Yes

Continuity of protective circuit with 200mA

Yes

Insulation with voltage 50, 100, 250, 500, 1000VDC

Yes

Time/Current tripping of A, AC General, Selective and Delayed RCDs up to 1000mA

Yes

Time/Current tripping of type B RCDs up to 300mA

Yes

Tripping time and current of RCDs with separate clamp jaws type B, A, AC Standard, Selective and Delayed up to 10A

Yes

Loop impedance P-N, P-P, P-PE and calculation of prospective short-circuit current

Yes

Line/Loop impedance with high resolution (with optional accessory IMP57)

Yes

Percentage voltage drop on the line

Yes

Measurement and recording of leakage currents and environment parameters

Yes

Three-phase Power quality and Energy consumption analysis:

Yes

9 types of electrical systems

1Φ-2wires, 1Φ-split phase, 3Φ-3 wires, 3Φ-Aron, 3Φ-Open Δ, 3Φ-Open Y, 3Φ-2 el. 1/2, 3Φ-4 wires Y, 3Φ-High Leg.

632 parameters can be recorded for over two months

Yes

Voltage Anomalies (dips and peaks) with a resolution of 20ms

@50Hz

Measurement/recording of Active, Reactive, Apparent Power

Yes

Measurement/recording of Active, Reactive, Apparent Energy

Yes

Measurement/recording of Cosphi, Power Factor

Yes

Measurement/Recording of Voltage and Current Harmonics up to 49th with THD%

Yes

Voltage/current vector diagram

Yes

Voltage/current waveforms

Yes

Tables or histograms of Harmonics and THD%

Yes

Summary table of main electric parameters

Yes

Help on line on the display

Yes

Protection category

CAT IV

Guidelines

EMC: IEC/EN61326
EN50160
EN50522
EN60909-0
EN61936-1
IEC/EN61010-031
IEC/EN61010-1
IEC/EN61010-2-032
IEC/EN61187
IEC/EN61557-1
IEC/EN61557-10
IEC/EN61557-2
IEC/EN61557-3
IEC/EN61557-4
IEC/EN61557-5
IEC/EN61557-6
IEC/EN61557-7
UNE20460

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

Compare products

{"one"=>"Select 2 or 3 items to compare", "other"=>"{{ count }} of 3 items selected"}

Select first item to compare

Select second item to compare

Select third item to compare

Compare