تخطى الى المحتوى

cGas Analog Detector for Indoor Public Spaces Carbon monoxide Sensor

يصنع : CRITICAL ENVIRONMENT TECHNOLOGIES
نموذج : CGAS-AP-CO
ضمان : 1 Year
التوفر : في الأوراق المالية
السعر الأصلي AED 2,400.00 - السعر الأصلي AED 2,400.00
السعر الأصلي
AED 2,400.00
AED 2,400.00 - AED 2,400.00
السعر الحالي AED 2,400.00
(بما في ذلك ضريبة القيمة المضافة)

cGas Analog Detector for Indoor Public Spaces Carbon monoxide Sensor

This cGas Detector is designed for use in publicly occupied spaces where integrated demand-controlled ventilation (DCV) is used for air quality and energy savings; for continuous monitoring of refrigerants where high-efficiency, high volume refrigerant cooling and heating systems (VRF) are used to keep the indoor environment comfortable; and for other continuous monitoring of hazardous gases in publicly frequented areas. The low profile, aesthetically pleasing enclosure is designed to reduce the noticeability of the device by the public eye.

Both the analog and digital models are powered by 24 VDC or ground referenced AC, come with an LCD display, temperature compensation and thermal resetting fuse. Sensor replacement is easy with true Plug & Play smart sensors that arrive pre-calibrated. The firmware and configuration can be upgraded in the field using the USB connection.

The digital models are user configurable in the field for BACnet® MS-TP RS-485 or Modbus® RTU RS-485 output for communicating with a controller, Building Automation System or other control panel.

Both the analog and digital models may be configured with an internal gas sensor or a remote refrigerant sensor (dongle). The internal sensor model is ideal for vertical terminal air conditioner (VTAC) systems. The remote refrigerant sensor model has a 9m / 29.5ft dongle cable that is ideal for use in packaged terminal air conditioner (PTAC) applications.

  • Key Features

    • Analog models have one 4-20 mA analog output or 0-10 volt or 2-10 volt output
    • Digital models have user in the field configurable BACnet® MS/TP RS-485 or Modbus® RTU RS-485 digital output signal to a BAS
    • Easy Plug & Play Smart Sensor replacement at end of life
    • Pre-calibrated replacement sensors
    • Bright LCD display with configurable visual alarm
    • 1 SPDT dry contact relay, rated 30 volts, 2 amps max with or without internal buzzer*
    • Models available with user selectable 1PM, 2.5PM or 10PM particulate sensor
    • Optional RH & Temperature sensor (Option -RHT)
    • Low profile to reduce noticeability in public spaces
    • USB port for configuration changes and firmware upgrades
    • RoHS compliant circuit boards
  • Applications

    • Hotels
    • Office Buildings
    • Hospitals
    • Apartment Buildings
    • Retirement Homes
    • Theatres / Auditoriums
    • Schools / Universities / Dormitories
Enclosure

 White polycarbonate, low-profile design.

 

Weight

 400 g (14 oz)

 

Size

 124.9 x 124.9 x 50.0 mm (4.9 x 4.9 x 2.0 inches)

 

Power Requirement

 16-30 VDC, 3W; 12-27 VAC, 50-60 Hz, 3 VA

 

Operating Temperature

 0°C to 40°C (32°F to 104°F)

 

Operating Humidity

 15% - 90% RH non-condensing

 

Output Options One 4-20 mA output or jumper-selectable 0-10 V, 2-10 V analog output; BACnet® MS/TP RS-485 or Modbus® RTU RS-485.
Relay & Buzzer

 1 SPDT relay rated 30 volts, 2 amps max, with an internal buzzer rated 90 dB @ 10 cm.

 

Certifications

 Conforms to CSA-C22.2 No. 205-12, UL508, EMC Directive 2014/30/EU, EN 50270, 2015.

 

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

How does the cGas Digital Detector communicate with building automation systems?

It supports BACnet® MS/TP and Modbus® RTU RS-485 communication protocols, allowing seamless integration with various building automation systems.

Can the sensor be replaced easily?

Yes, the cGas Detector features plug-and-play smart sensors that are pre-calibrated for simple and quick replacement.

Does the detector provide real-time carbon monoxide readings?

Yes, it has an LCD display that provides real-time CO level readings, allowing for immediate monitoring of indoor air quality.

What power source is required for this detector?

The detector operates on 16-30 VDC or 12-27 VAC, providing flexibility for different installation environments.

Is it possible to monitor temperature and humidity with this device?

Yes, an optional RH & Temperature sensor (Option -RHT) can be added to monitor both temperature and humidity alongside CO levels.

Is the cGas Digital Detector suitable for use in areas like hospitals and office buildings?

Yes, the device is designed for publicly occupied spaces and its low-profile design is ideal for discreet monitoring in environments like hospitals, offices, schools, and hotels. 

cGas Analog Detector for Indoor Public Spaces Carbon monoxide Sensor

This cGas Detector is designed for use in publicly occupied spaces where integrated demand-controlled ventilation (DCV) is used for air quality and energy savings; for continuous monitoring of refrigerants where high-efficiency, high volume refrigerant cooling and heating systems (VRF) are used to keep the indoor environment comfortable; and for other continuous monitoring of hazardous gases in publicly frequented areas. The low profile, aesthetically pleasing enclosure is designed to reduce the noticeability of the device by the public eye.

Both the analog and digital models are powered by 24 VDC or ground referenced AC, come with an LCD display, temperature compensation and thermal resetting fuse. Sensor replacement is easy with true Plug & Play smart sensors that arrive pre-calibrated. The firmware and configuration can be upgraded in the field using the USB connection.

The digital models are user configurable in the field for BACnet® MS-TP RS-485 or Modbus® RTU RS-485 output for communicating with a controller, Building Automation System or other control panel.

Both the analog and digital models may be configured with an internal gas sensor or a remote refrigerant sensor (dongle). The internal sensor model is ideal for vertical terminal air conditioner (VTAC) systems. The remote refrigerant sensor model has a 9m / 29.5ft dongle cable that is ideal for use in packaged terminal air conditioner (PTAC) applications.

  • Key Features

    • Analog models have one 4-20 mA analog output or 0-10 volt or 2-10 volt output
    • Digital models have user in the field configurable BACnet® MS/TP RS-485 or Modbus® RTU RS-485 digital output signal to a BAS
    • Easy Plug & Play Smart Sensor replacement at end of life
    • Pre-calibrated replacement sensors
    • Bright LCD display with configurable visual alarm
    • 1 SPDT dry contact relay, rated 30 volts, 2 amps max with or without internal buzzer*
    • Models available with user selectable 1PM, 2.5PM or 10PM particulate sensor
    • Optional RH & Temperature sensor (Option -RHT)
    • Low profile to reduce noticeability in public spaces
    • USB port for configuration changes and firmware upgrades
    • RoHS compliant circuit boards
  • Applications

    • Hotels
    • Office Buildings
    • Hospitals
    • Apartment Buildings
    • Retirement Homes
    • Theatres / Auditoriums
    • Schools / Universities / Dormitories
Enclosure

 White polycarbonate, low-profile design.

 

Weight

 400 g (14 oz)

 

Size

 124.9 x 124.9 x 50.0 mm (4.9 x 4.9 x 2.0 inches)

 

Power Requirement

 16-30 VDC, 3W; 12-27 VAC, 50-60 Hz, 3 VA

 

Operating Temperature

 0°C to 40°C (32°F to 104°F)

 

Operating Humidity

 15% - 90% RH non-condensing

 

Output Options One 4-20 mA output or jumper-selectable 0-10 V, 2-10 V analog output; BACnet® MS/TP RS-485 or Modbus® RTU RS-485.
Relay & Buzzer

 1 SPDT relay rated 30 volts, 2 amps max, with an internal buzzer rated 90 dB @ 10 cm.

 

Certifications

 Conforms to CSA-C22.2 No. 205-12, UL508, EMC Directive 2014/30/EU, EN 50270, 2015.

 

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

How does the cGas Digital Detector communicate with building automation systems?

It supports BACnet® MS/TP and Modbus® RTU RS-485 communication protocols, allowing seamless integration with various building automation systems.

Can the sensor be replaced easily?

Yes, the cGas Detector features plug-and-play smart sensors that are pre-calibrated for simple and quick replacement.

Does the detector provide real-time carbon monoxide readings?

Yes, it has an LCD display that provides real-time CO level readings, allowing for immediate monitoring of indoor air quality.

What power source is required for this detector?

The detector operates on 16-30 VDC or 12-27 VAC, providing flexibility for different installation environments.

Is it possible to monitor temperature and humidity with this device?

Yes, an optional RH & Temperature sensor (Option -RHT) can be added to monitor both temperature and humidity alongside CO levels.

Is the cGas Digital Detector suitable for use in areas like hospitals and office buildings?

Yes, the device is designed for publicly occupied spaces and its low-profile design is ideal for discreet monitoring in environments like hospitals, offices, schools, and hotels. 

قارن بين المنتجات

{"one"=>"حدد 2 أو 3 عناصر للمقارنة", "other"=>"تم اختيار {{ count }} من 3 عناصر"}

حدد العنصر الأول للمقارنة

حدد العنصر الثاني للمقارنة

حدد العنصر الثالث للمقارنة

يقارن