Multi Function Multimeter RCD Tester- Jupiter
HT revolutionizes the portable instrument market by introducing the new JUPITER.
The first multimeter who incorporates the functions available only in standard electrical safety testers and professional High-end multimeters.
Features :
- DC, AC TRMS, AC+DC TRMS current by means of external clamp transducer
- AC TRMS current by means of external flexible transducer F3000U
- Resistance and continuity test with buzzer
- RCD tripping time & RCD trip current measurement
- Non-trip earth resistance
- Voltage and current harmonics up to the 25th and THD%
- Loop impedance P-N, P-P, P-PE and calculation of prospective short-circuit current
- Electric motor starting current (INRUSH)
- Phase sequence
- \n \n \n \n
Measuring counts |
6000 |
---|---|
DC, AC TRMS, AC+DC TRMS current by means of external clamp transducer |
Yes |
TRMS |
Yes |
AC TRMS current by means of external flexible transducer F3000U |
Yes |
AC/DC voltage |
690V / AC+DC |
LoZ Input |
Yes |
AC/DC current |
AC+DC with external clamp transducer |
Resistance and continuity test with buzzer |
Yes |
Frequency |
Yes |
RCD tripping time |
30mA, 100mA, 300mA A/AC |
RCD trip current measurement |
RCD A/AC 30mA |
Leakage current (with optional accessory HT96U) |
Yes |
Non-trip earth resistance |
Yes |
Voltage and current harmonics up to the 25th and THD% |
Yes |
Loop impedance P-N, P-P, P-PE and calculation of prospective short-circuit current |
Yes |
Electric motor starting current (INRUSH) |
Yes |
Auto x1/2, x1, x2, x5, 0°, 180° |
Yes |
Phase sequence |
Yes |
Out come OK/NOT OK |
According to IEC60364-6 |
Backlit LCD display |
Yes |
MAX/MIN/HOLD |
Yes |
Bargraph |
Yes |
Measurement category |
CAT IV 600V / CAT III 690V |
Weight in grams (batteries included) |
420 |
Size (LxWxH) (mm) |
175x85x55 |
Guidelines |
CEI 64-8 612.6.3 |
Multi Function Multimeter RCD Tester- Jupiter
HT revolutionizes the portable instrument market by introducing the new JUPITER.
The first multimeter who incorporates the functions available only in standard electrical safety testers and professional High-end multimeters.
Features :
- DC, AC TRMS, AC+DC TRMS current by means of external clamp transducer
- AC TRMS current by means of external flexible transducer F3000U
- Resistance and continuity test with buzzer
- RCD tripping time & RCD trip current measurement
- Non-trip earth resistance
- Voltage and current harmonics up to the 25th and THD%
- Loop impedance P-N, P-P, P-PE and calculation of prospective short-circuit current
- Electric motor starting current (INRUSH)
- Phase sequence
- \n \n \n \n
Measuring counts |
6000 |
---|---|
DC, AC TRMS, AC+DC TRMS current by means of external clamp transducer |
Yes |
TRMS |
Yes |
AC TRMS current by means of external flexible transducer F3000U |
Yes |
AC/DC voltage |
690V / AC+DC |
LoZ Input |
Yes |
AC/DC current |
AC+DC with external clamp transducer |
Resistance and continuity test with buzzer |
Yes |
Frequency |
Yes |
RCD tripping time |
30mA, 100mA, 300mA A/AC |
RCD trip current measurement |
RCD A/AC 30mA |
Leakage current (with optional accessory HT96U) |
Yes |
Non-trip earth resistance |
Yes |
Voltage and current harmonics up to the 25th and THD% |
Yes |
Loop impedance P-N, P-P, P-PE and calculation of prospective short-circuit current |
Yes |
Electric motor starting current (INRUSH) |
Yes |
Auto x1/2, x1, x2, x5, 0°, 180° |
Yes |
Phase sequence |
Yes |
Out come OK/NOT OK |
According to IEC60364-6 |
Backlit LCD display |
Yes |
MAX/MIN/HOLD |
Yes |
Bargraph |
Yes |
Measurement category |
CAT IV 600V / CAT III 690V |
Weight in grams (batteries included) |
420 |
Size (LxWxH) (mm) |
175x85x55 |