Skip to content

cGas Detector IR Refrigerant Transmitter R227EA Sensor

MAKE : CRITICAL ENVIRONMENT TECHNOLOGIES
MODEL : CGAS-A-IR227EA
WARRANTY : 1 Year
AVAILABILITY : IN STOCK
Original price AED 6,200.00 - Original price AED 6,200.00
Original price
AED 6,200.00
AED 6,200.00 - AED 6,200.00
Current price AED 6,200.00
(Including VAT)

cGas Detector IR Refrigerant Transmitter R227EA Sensor

The cGas Detector IR Refrigerant provides continuous monitoring of a wide range of refrigerant gases commonly used in commercial refrigeration systems. Dual beam, non-dispersive infrared sensor technology overcomes the limitations of solid state refrigerant sensors, accurately detects refrigerant gases without cross interference from toxic or combustible gases and is low maintenance with a longer lifespan. Choose from many types of refrigerant gas sensors commonly used in commercial refrigeration systems, including A2L refrigerants, SF6 and CO2 (R744). True Plug & Play Smart Sensor technology makes replacing sensors quick and easy.

The cGas Detector IR Refrigerant is available with analog output or digital output and comes with a relay and internal audible alarm. Powered by 24 VDC or ground referenced AC, it has an LCD display, temperature compensation, thermal resetting fuse and the firmware and configuration can be upgraded in the field using the USB connection. It comes in a standard water / dust tight, corrosion resistant ABS/ polycarbonate enclosure with a hinged, secured door. With the optional, factory installed splash guard the enclosure is IP54 rated and provides protection in water spray or wash down applications.

Complies with refrigeration safety codes ASHRAE No 15-2001 Mechanical Standard and B-52 Code.

Key Features

  • Accurate, low level leak detection
  • Long life, non-dispersive infrared refrigerant sensor, dual beam technology
  • Easy Plug & Play Smart Sensor replacement at end of life, comes pre-calibrated
  • One linear 4-20 mA or 0-10V analog output or field configurable BACnet® MS/TP RS-485 or Modbus® RTU RS-485 digital output signal to a BAS
  • 1 SPDT relay rated 30 volts, 2 amp max
  • Internal audible alarm rated 90 dB @10 cm/4 in
  • 24 VDC or VAC power (ground reference)
  • Bright LCD display
  • USB port for configuration changes and firmware upgrades
  • Standard water / dust tight, corrosion resistant enclosure (drip proof); IP54 rated with optional splash guard (Option -S) installed
  • RoHS compliant circuit boards

Applications

  • Supermarkets
  • Convenience Stores
  • Grocery Stores
  • Refrigerated Mechanical Rooms
  • Commercial Chiller Equipment Rooms
  • Food Storage / Cold Storage Rooms
  • Walk-in Freezers
  • Food Processing Plants
  • Food Service Facilities
Target Gas

 Infrared R227EA refrigerant (0-2,000 ppm)

 

Enclosure ABS/polycarbonate, IP54 rated with splash guard; corrosion-resistant and RF interference-reducing copper-coated interior.
Weight

 400 g (14 oz)

 

Size

 127 x 127 x 76 mm (5.0 x 5.0 x 3.0 inches)

 

Power Requirement

 16-30 VDC, 3W; 12-27 VAC, 50-60 Hz, 3 VA

 

Operating Temperature

 0°C to 40°C (32°F to 104°F); with low-temperature package,  -40°C to 40°C (-40°F to 104°F)

 

Operating Humidity

 15% - 85% RH non-condensing

 

Analog Output

 One 4-20 mA output or selectable 0-10 V output

 

Internal Relay

 1 SPDT relay rated 30 volts, 2 amps

 

Certifications Conforms to CSA-C22.2 No. 205-12, UL508, EMC Directive 2014/30/EU, EN 50270, 2015; RoHS compliant circuit boards.

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

How does the cGas Detector handle sensor replacement?

The detector features plug-and-play smart sensors that are pre-calibrated for quick and easy replacement, minimizing downtime.

What output options does this detector provide?

It offers one linear 4-20 mA or 0-10 V analog output and supports BACnet® MS/TP RS-485 or Modbus® RTU RS-485 digital output for seamless integration with building systems.

Does the cGas Detector provide real-time leak detection?

Yes, the built-in LCD display provides real-time monitoring of refrigerant levels, ensuring continuous leak detection.

Is this detector suitable for low-temperature environments?

Yes, the optional low-temperature package allows the detector to operate effectively in environments as cold as -40°C.

How is the detector protected against harsh conditions?

It features a corrosion-resistant ABS/polycarbonate enclosure and is IP54 rated with the optional splash guard, providing water and dust protection.

What power supply does the detector require?

It operates on 16-30 VDC or 12-27 VAC, making it versatile for different installation environments.

cGas Detector IR Refrigerant Transmitter R227EA Sensor

The cGas Detector IR Refrigerant provides continuous monitoring of a wide range of refrigerant gases commonly used in commercial refrigeration systems. Dual beam, non-dispersive infrared sensor technology overcomes the limitations of solid state refrigerant sensors, accurately detects refrigerant gases without cross interference from toxic or combustible gases and is low maintenance with a longer lifespan. Choose from many types of refrigerant gas sensors commonly used in commercial refrigeration systems, including A2L refrigerants, SF6 and CO2 (R744). True Plug & Play Smart Sensor technology makes replacing sensors quick and easy.

The cGas Detector IR Refrigerant is available with analog output or digital output and comes with a relay and internal audible alarm. Powered by 24 VDC or ground referenced AC, it has an LCD display, temperature compensation, thermal resetting fuse and the firmware and configuration can be upgraded in the field using the USB connection. It comes in a standard water / dust tight, corrosion resistant ABS/ polycarbonate enclosure with a hinged, secured door. With the optional, factory installed splash guard the enclosure is IP54 rated and provides protection in water spray or wash down applications.

Complies with refrigeration safety codes ASHRAE No 15-2001 Mechanical Standard and B-52 Code.

Key Features

  • Accurate, low level leak detection
  • Long life, non-dispersive infrared refrigerant sensor, dual beam technology
  • Easy Plug & Play Smart Sensor replacement at end of life, comes pre-calibrated
  • One linear 4-20 mA or 0-10V analog output or field configurable BACnet® MS/TP RS-485 or Modbus® RTU RS-485 digital output signal to a BAS
  • 1 SPDT relay rated 30 volts, 2 amp max
  • Internal audible alarm rated 90 dB @10 cm/4 in
  • 24 VDC or VAC power (ground reference)
  • Bright LCD display
  • USB port for configuration changes and firmware upgrades
  • Standard water / dust tight, corrosion resistant enclosure (drip proof); IP54 rated with optional splash guard (Option -S) installed
  • RoHS compliant circuit boards

Applications

  • Supermarkets
  • Convenience Stores
  • Grocery Stores
  • Refrigerated Mechanical Rooms
  • Commercial Chiller Equipment Rooms
  • Food Storage / Cold Storage Rooms
  • Walk-in Freezers
  • Food Processing Plants
  • Food Service Facilities
Target Gas

 Infrared R227EA refrigerant (0-2,000 ppm)

 

Enclosure ABS/polycarbonate, IP54 rated with splash guard; corrosion-resistant and RF interference-reducing copper-coated interior.
Weight

 400 g (14 oz)

 

Size

 127 x 127 x 76 mm (5.0 x 5.0 x 3.0 inches)

 

Power Requirement

 16-30 VDC, 3W; 12-27 VAC, 50-60 Hz, 3 VA

 

Operating Temperature

 0°C to 40°C (32°F to 104°F); with low-temperature package,  -40°C to 40°C (-40°F to 104°F)

 

Operating Humidity

 15% - 85% RH non-condensing

 

Analog Output

 One 4-20 mA output or selectable 0-10 V output

 

Internal Relay

 1 SPDT relay rated 30 volts, 2 amps

 

Certifications Conforms to CSA-C22.2 No. 205-12, UL508, EMC Directive 2014/30/EU, EN 50270, 2015; RoHS compliant circuit boards.

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

How does the cGas Detector handle sensor replacement?

The detector features plug-and-play smart sensors that are pre-calibrated for quick and easy replacement, minimizing downtime.

What output options does this detector provide?

It offers one linear 4-20 mA or 0-10 V analog output and supports BACnet® MS/TP RS-485 or Modbus® RTU RS-485 digital output for seamless integration with building systems.

Does the cGas Detector provide real-time leak detection?

Yes, the built-in LCD display provides real-time monitoring of refrigerant levels, ensuring continuous leak detection.

Is this detector suitable for low-temperature environments?

Yes, the optional low-temperature package allows the detector to operate effectively in environments as cold as -40°C.

How is the detector protected against harsh conditions?

It features a corrosion-resistant ABS/polycarbonate enclosure and is IP54 rated with the optional splash guard, providing water and dust protection.

What power supply does the detector require?

It operates on 16-30 VDC or 12-27 VAC, making it versatile for different installation environments.