Power Quality and Energy Consumption Analyzer VEGA78
It allows the analysis of all electric parameters which can be measured nowadays, elaborating them easily and quickly. This device can be easily programmed thanks to the new colour touchscreen display with icon menu style, which guarantees the selection of internal parameters in a simple and intuitive way.Each internal parameter is easily reached through the typical tree structure, widely known to Windows system users. The device allows displaying the parameters in numerical and graphic mode, both for periodical analysis and for harmonic analysis. The graphic function “vector diagram” allows, among other things, to immediately evaluate the phase angle between input voltage and current signals, thus defining the loads’ nature. The 15MB internal memory allows saving recorded data for a remarkable number of consecutive days.VEGA78, compared to PQA820 allows current measurement up to 3000A and voltage up to 1000V. The Help online function available on each screen is a valid and concrete help for the operator in understanding how the devices are used.
AC voltage in single-phase/three-phase systems |
Yes |
---|---|
AC/DC current in single-phase/three-phase systems |
Yes |
Cosphi, Power Factor |
Yes |
Voltage unbalance (NEG%, ZERO%) |
Yes |
Active, reactive, apparent power/energy and DC power |
Yes |
Voltage and current harmonics up to the 49th with THD |
In real time up to 64th |
Voltage anomalies (dips, peaks) with a resolution of 10ms (@ 50Hz) |
Yes |
Phase sequence |
Yes |
Neutral-Ground Voltage |
Yes |
Neutral current |
Yes |
Max number of simultaneously selectable parameters |
251 |
Recording with selectable integration period |
1s-60m |
Indicative memory duration (in days @ PI=10min @ max number of parameters) |
90 days |
Indication of recording duration |
Yes |
Internal memory capacity |
15MB |
External compact flash card |
Optional |
Default and custom recordings |
Yes |
Indication of Saving instant sampled valuesrecording duration |
Yes |
Summary table of main electric parameters |
Yes |
Voltage/current waveforms |
Yes |
Tables or histograms of Harmonics and THD% |
In real time up to 64th |
Voltage/current vector diagram |
Yes |
Measurement category |
CAT IV 600V |
Measurement with use of external TA and TV (with optional accessory HT903) |
Yes |
Touchscreen colour display |
Yes |
Power supply with rechargeable battery |
Yes |
Auto power off |
Yes |
USB port for data download onto Pen Drive |
Yes |
Provided PC interface with software for Windows |
USB |
Context help active on each screen |
Yes |
Protection password on recording |
Yes |
Size (LxWx H) (mm) |
235x165x75 |
Weight in grams (batteries included) |
1000 |
Guidelines |
CE MARK |
Power Quality and Energy Consumption Analyzer VEGA78
It allows the analysis of all electric parameters which can be measured nowadays, elaborating them easily and quickly. This device can be easily programmed thanks to the new colour touchscreen display with icon menu style, which guarantees the selection of internal parameters in a simple and intuitive way.Each internal parameter is easily reached through the typical tree structure, widely known to Windows system users. The device allows displaying the parameters in numerical and graphic mode, both for periodical analysis and for harmonic analysis. The graphic function “vector diagram” allows, among other things, to immediately evaluate the phase angle between input voltage and current signals, thus defining the loads’ nature. The 15MB internal memory allows saving recorded data for a remarkable number of consecutive days.VEGA78, compared to PQA820 allows current measurement up to 3000A and voltage up to 1000V. The Help online function available on each screen is a valid and concrete help for the operator in understanding how the devices are used.
AC voltage in single-phase/three-phase systems |
Yes |
---|---|
AC/DC current in single-phase/three-phase systems |
Yes |
Cosphi, Power Factor |
Yes |
Voltage unbalance (NEG%, ZERO%) |
Yes |
Active, reactive, apparent power/energy and DC power |
Yes |
Voltage and current harmonics up to the 49th with THD |
In real time up to 64th |
Voltage anomalies (dips, peaks) with a resolution of 10ms (@ 50Hz) |
Yes |
Phase sequence |
Yes |
Neutral-Ground Voltage |
Yes |
Neutral current |
Yes |
Max number of simultaneously selectable parameters |
251 |
Recording with selectable integration period |
1s-60m |
Indicative memory duration (in days @ PI=10min @ max number of parameters) |
90 days |
Indication of recording duration |
Yes |
Internal memory capacity |
15MB |
External compact flash card |
Optional |
Default and custom recordings |
Yes |
Indication of Saving instant sampled valuesrecording duration |
Yes |
Summary table of main electric parameters |
Yes |
Voltage/current waveforms |
Yes |
Tables or histograms of Harmonics and THD% |
In real time up to 64th |
Voltage/current vector diagram |
Yes |
Measurement category |
CAT IV 600V |
Measurement with use of external TA and TV (with optional accessory HT903) |
Yes |
Touchscreen colour display |
Yes |
Power supply with rechargeable battery |
Yes |
Auto power off |
Yes |
USB port for data download onto Pen Drive |
Yes |
Provided PC interface with software for Windows |
USB |
Context help active on each screen |
Yes |
Protection password on recording |
Yes |
Size (LxWx H) (mm) |
235x165x75 |
Weight in grams (batteries included) |
1000 |
Guidelines |
CE MARK |