Differential Pressure Transmitter CP 111

The CP 111 Differential Pressure Transmitter is an advanced and highly reliable device designed to measure differential pressure in a variety of industrial and environmental applications. Ideal for monitoring air and neutral gases, the CP 111 ensures precise measurements across a range of pressures with exceptional stability. Equipped with a self-calibration solenoid valve and an easy-to-install wall-mount system, this transmitter is perfect for critical environments where accuracy and long-term reliability are paramount.

Features

  • Self-Calibration Solenoid Valve: Automatically adjusts and calibrates the device, ensuring long-term measurement stability.
  • High Accuracy: Delivers measurements with an accuracy of ±1% of reading, ensuring reliable performance in critical applications.
  • Wide Measurement Range: Measures pressures from -100/+100 Pa to -2000/+2000 mbar, accommodating a variety of monitoring needs.
  • Configurable Outputs: Offers 0-10 V or 4-20 mA active outputs, or a 4-20 mA passive loop output, depending on the application.
  • Rugged Construction: Housed in an ABS V0 enclosure with IP65 protection, providing resistance against dust and water ingress.
  • Simple Installation: Features a "¼ turn" wall-mount system with a quick installation plate, making setup easy and efficient.
  • LCD Display Option: Available with a 10-digit LCD display for real-time monitoring of pressure readings.

 

Measuring Range

 -100/+100 Pa to -2000/+2000 mbar

 

Accuracy

 ±1% of reading ±2 Pa

 

Output

 

 

Active

 0-10 V or 4-20 mA (24 Vac/Vdc ±10%)

 

Passive

 4-20 mA loop-powered (16-30 Vdc)

 

Housing Material

 ABS V0 as per UL94

 

Protection Class

 IP65

 

Display

 Optional 10-digit LCD, size 50 x 17 mm

 

Overpressure Tolerance

 Up to 4100 mbar

 

Response Time

 0.3 seconds (63% of final value)

 

Operating Temperature

 0 to +50°C

 

Storage Temperature

 -10 to +70°C

 

Power Consumption

 3 VA (0-10 V) or 3 VA (4-20 mA)

 

Dimensions

 170 x 105 x 54 mm

 

Weight

 143 g

 

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

Q1: What is the primary use of the CP 111 Differential Pressure Transmitter?

A1: The CP 111 is used for measuring differential pressure in HVAC systems, cleanrooms, and industrial applications, ensuring accurate monitoring of air and neutral gases.

Q2: How does the self-calibration feature work?

A2: The CP 111 is equipped with a solenoid valve that automatically calibrates the device to maintain accuracy over time, even in low and high-pressure ranges.

Q3: Can the CP 111 be used in harsh environments?

A3: Yes, the CP 111 is housed in an IP65-rated ABS enclosure, providing protection against dust and water, making it suitable for challenging environments.

Q4: What are the output options available with the CP 111?

A4: The CP 111 offers 0-10 V or 4-20 mA active outputs, as well as a 4-20 mA passive loop output, depending on your system requirements.

Q5: Is the CP 111 easy to install?

A5: Yes, the CP 111 features a "¼ turn" wall-mount system with a quick installation plate, making it easy and efficient to install.

Q6: Does the CP 111 come with a display?

A6: The CP 111 is available with or without a digital LCD display, allowing you to choose based on your monitoring needs.

Differential Pressure Transmitter CP 111

The CP 111 Differential Pressure Transmitter is an advanced and highly reliable device designed to measure differential pressure in a variety of industrial and environmental applications. Ideal for monitoring air and neutral gases, the CP 111 ensures precise measurements across a range of pressures with exceptional stability. Equipped with a self-calibration solenoid valve and an easy-to-install wall-mount system, this transmitter is perfect for critical environments where accuracy and long-term reliability are paramount.

Features

  • Self-Calibration Solenoid Valve: Automatically adjusts and calibrates the device, ensuring long-term measurement stability.
  • High Accuracy: Delivers measurements with an accuracy of ±1% of reading, ensuring reliable performance in critical applications.
  • Wide Measurement Range: Measures pressures from -100/+100 Pa to -2000/+2000 mbar, accommodating a variety of monitoring needs.
  • Configurable Outputs: Offers 0-10 V or 4-20 mA active outputs, or a 4-20 mA passive loop output, depending on the application.
  • Rugged Construction: Housed in an ABS V0 enclosure with IP65 protection, providing resistance against dust and water ingress.
  • Simple Installation: Features a "¼ turn" wall-mount system with a quick installation plate, making setup easy and efficient.
  • LCD Display Option: Available with a 10-digit LCD display for real-time monitoring of pressure readings.

 

Measuring Range

 -100/+100 Pa to -2000/+2000 mbar

 

Accuracy

 ±1% of reading ±2 Pa

 

Output

 

 

Active

 0-10 V or 4-20 mA (24 Vac/Vdc ±10%)

 

Passive

 4-20 mA loop-powered (16-30 Vdc)

 

Housing Material

 ABS V0 as per UL94

 

Protection Class

 IP65

 

Display

 Optional 10-digit LCD, size 50 x 17 mm

 

Overpressure Tolerance

 Up to 4100 mbar

 

Response Time

 0.3 seconds (63% of final value)

 

Operating Temperature

 0 to +50°C

 

Storage Temperature

 -10 to +70°C

 

Power Consumption

 3 VA (0-10 V) or 3 VA (4-20 mA)

 

Dimensions

 170 x 105 x 54 mm

 

Weight

 143 g

 

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

Q1: What is the primary use of the CP 111 Differential Pressure Transmitter?

A1: The CP 111 is used for measuring differential pressure in HVAC systems, cleanrooms, and industrial applications, ensuring accurate monitoring of air and neutral gases.

Q2: How does the self-calibration feature work?

A2: The CP 111 is equipped with a solenoid valve that automatically calibrates the device to maintain accuracy over time, even in low and high-pressure ranges.

Q3: Can the CP 111 be used in harsh environments?

A3: Yes, the CP 111 is housed in an IP65-rated ABS enclosure, providing protection against dust and water, making it suitable for challenging environments.

Q4: What are the output options available with the CP 111?

A4: The CP 111 offers 0-10 V or 4-20 mA active outputs, as well as a 4-20 mA passive loop output, depending on your system requirements.

Q5: Is the CP 111 easy to install?

A5: Yes, the CP 111 features a "¼ turn" wall-mount system with a quick installation plate, making it easy and efficient to install.

Q6: Does the CP 111 come with a display?

A6: The CP 111 is available with or without a digital LCD display, allowing you to choose based on your monitoring needs.